    JH-TCQ gas detector

    Your current location : Home >> Products >> Toxic gas detector
    • http://jcpk10.cn/data/images/product/1569227234198.jpg
    • JH-TCQ gas detector

    • Product Category: Toxic Gas Detector

    • Order hotline: 400-6515-966

    • More
    • I want to make an inquiry
    Detailed introduction

    JH-TCQ-XX (BFL)

    JH-TCQ-XX(BFL).jpg


    Product introduction:
    The imported electrochemical sensor is used. It applies the principle of controlled potential electrolysis. Its structure is to place three electrodes in the electrolytic cell, namely the working electrode, the counter electrode and the reference electrode, and apply a certain polarization voltage to replace different gases. The sensor can change the value of the polarization voltage to measure different toxic and harmful gases. The measured gas reaches the working electrode through the membrane, and a redox reaction occurs. The sensor will output a small current at this time. This current is proportional to the concentration of the toxic and harmful gas. This current signal is converted into a voltage by sampling and the voltage signal is amplified. After voltage and current conversion, the content (ppm value) in the detection range of toxic and harmful gases is converted into 4-20mA standard signal output.


    Features:
    ☞ The imported electrochemical sensor has the characteristics of strong gas selectivity, short response time, long service life, high accuracy, and strong anti-interference.
    ☞ It can detect various toxic gases in the indoor and outdoor environment and transmit the detection signal to the gas alarm controller ;
    ☞The shell is made of cast aluminum alloy, the surface is painted, explosion-proof, dust-proof and corrosion-resistant, which can meet the requirements of various environments.
    ☞ This detector can be connected to any secondary instrument or control system capable of receiving 4-20mA standard signals;


    Detection gas:

    Hydrogen, oxygen, acetone, ethylene oxide, ammonia, chlorine, hydrogen sulfide, carbon monoxide, nitrogen monoxide, nitrogen dioxide, sulfur dioxide
    Phosgene, hydrogen chloride, phosphine, arsenide, chlorine dioxide, hydrogen cyanide,
    Various toxic and harmful gases such as toluene, acetylene, chloroform (trichloromethane)


    Application areas:
    Petroleum, chemical, metallurgy, coking, pharmaceutical, sewage treatment, boiler room, hotel and other special industries and environmental fields.


    Technical indicators:

    project

    Description

    project

    Description

    working principle

    Electrochemical

    Explosion-proof grade

    Ex d IIC T6

    Detection gas

    See product attached sheet

    Protection class

    IP65

    scope of test

    See product attached sheet

    Electrical Interface

    G 1/2

    Power consumption

    ≤3W

    Operating Voltage

    12 ~ 24V DC

    output signal

    4-20mA standard signal

    Sensor life

    2 years (in the air)

    connecting cables

    RVVP3 × 0.75mm2 shielded cable

    model

    JH-TCQ-port (BF)

    Operating temperature

    See measured gas for details

    Zero drift

    ≤ ± 2% FS / year

    environment humidity

    10% -95% RH (non-condensing)

    Reaction time

    See measured gas for details

    Detection accuracy

    ± 5% FS

    annex

    Manual, remote control, sound and light alarm selection


    Attachment: See table for common gas technical parameters

    project

    Description

    project

    Description

    working principle

    Electrochemical

    Explosion-proof grade

    Ex d IIC T6

    Detection gas

    For details, please refer to the appendix: Common Gas Technical Parameters

    Protection class

    IP65

    scope of test

    For details, please refer to the appendix: Common Gas Technical Parameters

    Electrical Interface

    G 1/2

    Power consumption

    ≤3W

    Working power

    18 ~ 30V DC

    output signal

    RS485

    Sensor life

    2 years (in the air)

    connecting cables

    RVVP4 × 1.5mm2 shielded cable

    model

    JH-TCQ-port (BZ)

    Operating temperature

    For details, please refer to the appendix: Common Gas Technical Parameters

    environment humidity

    10% -95% RH (non-condensing)

    Detection accuracy

    ± 5% FS

    Zero drift

    ≤ ± 2% F · S / year

    Response time

    For details, please refer to the appendix: Common Gas Technical Parameters

    Attachments

    Manual, sound and light alarm, display and other functions optional


    Attachment: See table for common gas technical parameters

    Gas name

    Molecular formula

    scope of test

    Response time

    Operating temperature

    Sensor life

    Methane

    CH4

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    Acetylene

    C2H2

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    acetone

    C3H6O

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    Ethanol

    C2H5OH

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    Propane

    C3H8

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    Ethylene

    C2H4

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    hydrogen

    H2

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    Isopropanol

    C4H8O2

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    Methanol

    CH3OH

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    Ethanol

    C2H5

    0 ~ 100% LEL

    ≤15s

    -40 ~ 70 ℃

    36 months

    Carbon monoxide

    CO

    0 ~ 1000 ppm; 0 ~ 2000ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    oxygen

    O2

    0 ~ 30% VOL; 0-100% VOL

    ≤15s

    -20 ~ 50 ℃

    24 months

    Chlorine

    Cl2

    0 ~ 20ppm; 0 ~ 50ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    Ammonia

    NH3

    0 ~ 100ppm; 0 ~ 200ppm; 0 ~ 1000ppm

    ≤90s

    -20 ~ 40 ℃

    24 months

    Hydrogen sulfide

    H2S

    0 ~ 50ppm; 0 ~ 100ppm; 0 ~ 200ppm;

    ≤15s

    -20 ~ 50 ℃

    24 months

    hydrogen

    H2

    0 ~ 1000ppm; 0 ~ 2000ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Hydrogen fluoride

    HF

    0 ~ 10ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Nitric oxide

    NO

    0 ~ 250ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Nitrogen dioxide

    NO2

    0 ~ 20ppm; 0 ~ 50ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    Sulfur dioxide

    SO2

    0 ~ 20ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Ethylene oxide

    C2H4O

    0 ~ 10ppm

    ≤120s

    -20 ~ 50 ℃

    24 months

    benzene

    C6H6

    0-100ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Carbon disulfide

    CS2

    0-20ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    carbon dioxide

    ClO2

    0 ~ 10ppm

    ≤120s

    -20 ~ 50 ℃

    24 months

    Hydrogen cyanide

    HCN

    0-50ppm

    ≤50s

    -20 ~ 50 ℃

    24 months

    Acrylonitrile

    C2H3CN

    0 ~ 10ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    Hydrogen chloride

    HCl

    0 ~ 30ppm; 0 ~ 100ppm

    ≤30s

    -20 ~ 40 ℃

    24 months

    Phosphine

    PH3

    0 ~ 20ppm; 0 ~ 1000ppm; 0 ~ 2000ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Arsenide

    AsH3

    0 ~ 1ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Phosgene

    COCl2

    0 ~ 1ppm; 0-10ppm

    ≤120s

    -20 ~ 50 ℃

    24 months

    Hydrogen bromide

    HBr

    0 ~ 30ppm; 0 ~ 100ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    Chloroform

    CHCL3

    0 ~ 100ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    Methanol

    CH3OH

    0-20ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    ozone

    O3

    0-1ppm

    ≤15s

    -20 ~ 40 ℃

    24 months

    Silane

    SiH4

    0-50ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Phosphane

    PH3

    0-5ppm; 0-20ppm

    ≤15s

    -20 ~ 50 ℃

    24 months

    Thiol

    TMB

    0-50 ppm

    ≤30s

    -20 ~ 50 ℃

    12 months

    Tetrahydrothiophene

    C4H8S

    0-50 ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    Butanone

    C4H8O

    0-20ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    formaldehyde

    CH2O

    0-10ppm

    ≤30s

    -20 ~ 50 ℃

    24 months

    Since there are many types of gas, it is inconvenient to enumerate them one by one. If the required gas is not available, please contact our company.

    Contact: Contact person
    phone: Landline / mobile number
    Message content: Please enter your message here, we will contact you as soon as possible.
    Verification code:

    Related tags: Combustible gas detector , JH-TCQ gas detector price , JH-TCQ gas detector wholesale

    Previous : Nothing Next : CGD-ZK (BZ) Gas Detector

    Recently Viewed:

      online service
      share it